  Datasheet File OCR Text:
  technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 1 pmc highlights & features ? universal ac input range from 85vac to 264vac without power de - rating ? full aluminum casing for light weight and corrosion resistant handling ? high mtbf > 700,000 hrs. as per telcordia sr - 332 ? overvoltage / overcurrent / over temp erature protections ? ip 20 compliant (for pmc - 24v100w1aj) safety standards cb certified for worldwide use model number: pmc - 2 4 v 100 w1a x unit weight : 0. 41 kg dimensions ( h x w x d): 158 mm x 97 mm x 38 mm general description the new panel mount power supply is the latest offering from one of the world?s largest power supply manufacturers and solution providers - delta. the product range offe rs a nominal output voltage of 2 4 v, a wide temperature range from - 10c to +70c and a highly dependable minimum holdup time. the state - of - the - art design is made to withstand harsh industrial environments. what makes the product stands out from the crowd is its lightweight full aluminum body design which can withstand shock and vibration ac cording to iec60068 - 2. del ta?s panel mount power supply also offers overvoltage and overload protection. using a wide input voltage range design, it is compatible worldwide. the input also includes dc operating voltage from 12 5 - 375vdc. best of all, this excellent design and quality does not come with a big price tag. model information pmc panel mount power supply model number input v oltage range output v oltage output cur r ent pmc - 24 v10 0 w1a x 85- 2 64v ac (12 5 - 375vdc) 24 vdc 4.17a model numbering pmc 2 4 v 100 w 1 a x pmc series out put voltage output power single p hase delta standard a - terminal block connector j - ip 20 connector
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 2 specifications input ratings / characteristics nominal input v oltage 100- 240v ac input v oltage range 85- 264v ac nominal input f r equency 50- 60hz in put f r equency range 47- 63hz nominal dc input voltage 125- 250 vdc dc input voltage range 125- 375vdc input cur r ent < 2.0 a @ 1 15 vac, < 1 . 1 a @ 2 3 0vac e f ficiency at 100% load > 8 6 % @ 1 15 vac & 2 3 0 vac max inrush cur r ent < 5 0a @ 115vac, < 1 0 0 a @ 230vac power factor conform to en61000 - 3 - 2 , class a leakage cur r ent < 1 ma @ 240vac output ratings / characteristics nominal output v oltage 2 4 vdc output v oltage t olerance 2 % (initial set point tolerance from factory ) output v oltage adjustment range 22- 28 vdc ou tput cur r ent 4.17 a output power 100 w line regulation < 0.5 % typ. (@ 85 - 2 64 vac input, 100% load ) load regulation < 1 % typ. (@ 85 - 2 64 vac input, 0 - 100% load ) pard (20mhz) < 15 0mvpp rise time < 3 0ms @ nominal input (100% load) start - up time < 10 00ms @ no minal input (100% load) hold - up time > 1 5 ms @ 115vac, > 9 0 ms @ 230vac (100% load) dynamic response (overshoot & undershoot o/p v oltage) 5% @ 0 - 100% load start - up with capacitive loads 8 , 0 00f max mechanical case cover alumin i um dimensions (l x w x d) 158 mm x 97 mm x 38 mm unit weight 0. 4 1 kg indicator green led (dc ok) cooling system convection terminal input and output pmc - 24v100w1aa: m3.5 x 7 p ins ( r ated 300v / 15a) pmc - 24v100w1aj: m3.5 x 7 pins (rated 300v/ 20a) wire awg 22 - 1 2 noise sound pressure level (spl) <40dba
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 3 environment surrounding air temperature operating - 10 c to + 7 0 c storage - 25c to + 85c power de - rating > 5 0 c de - rate power by 2.5% / c operating humidity < 95 % rh (non - condensing) operating altitude 3 ,000 meters shock test (non - operating) iec60068 - 2 - 27, 30g (300m/s2) for a duration of 18ms 3 times per direction, 18 times in total vibration (non - operating) iec60068 - 2 - 6, 10hz to 150hz @ 50m/s2 (5g peak); 90 min per axis for all x, y, z direction pollution degree 2 protections overvoltage < 32v 10%, selv output, hicc - up mode, non - latching (auto - recovery) overload / overcurrent > 120% of rated load current, hicc - up mode, non - latching (auto recovery) over temperature < 75 c surrounding air temperature @ 100% load, non - latching (auto - recovery) short circuit hicc - up mode, non - latching (auto - recovery when the fault is removed) protection against shock class i with pe* connection *pe: primary earth reliability data mtbf > 700,000 hrs, as per per telcordia sr - 332 expected cap life time 10 years (115vac & 230vac, 50% load @ 40c)
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 4 safety standards / directives electrical safety nemko bauart to en60950 - 1, ul/cul recognized to ul60950 - 1 and csa c22.2 no. 60950 - 1, cb sch eme to iec60950 - 1 , ccc to gb 4943 ce in conformance with emc directive 2004/108/ec and low voltage directive 2006/95/ec material and parts rohs directive 2011/65/eu compliant galvanic isolation input to output 3.0 kvac input to ground 1.5 kvac outp ut to ground 500 vac emc emc / emissions cispr22, en55022, fcc title 47: class b , gb925 4 immunity to electrostatic discharge iec 61000 - 4 - 2 level 4 criteria a 1) air discharge: 15 kv contact discharge: 8 kv radiated field iec 61000 - 4 - 3 level 3 criter ia a 1) 80mhz - 1ghz, 10v/m with 1khz tone / 80% modulation electrical fast transient / burst iec 61000 - 4 - 4 level 3 criteria a 1) 2kv surge iec610 0 0 - 4 - 5 level 3 criteria a 1) common mode 2) : 2kv differential mode 3) : 2 kv conducted iec 61000 - 4 - 6 level 3 cri teria a 1) 150khz - 80mhz, 10vrms power frequency magnetic fields iec 61000 - 4 - 8 criteria a 1) 1 0a/meter voltage dips iec 61000 - 4 - 11 100% dip; 1 cycle (20ms); self recoverable low energy pulse test (ring wave) iec61000 - 4 - 12 level 3 criteria a 1) common mo de 2) : 2kv differential mode 3) : 1kv 1) criteria a: normal performance within the specification limits 2) asymmetrical: common mode (line to earth) 3) symmetrical: differential mode (line to line)
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 5 block diagram device description 1 ) input & output terminal block connector 2 ) dc voltage adjustment potentiometer 3 ) dc ok control led (green)
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 6 dimensions h x w x d: 15 8 x 97 x 38 mm engineering data de- rating vs surrounding air temperature fig. 1 de - rating for vertical and horizontal mounting orientation > 5 0 c de - rate power by 2.5% / c note 1 . power supply components may degrade, or be damag ed, when the power supply is continuously used outside the shaded region, refer to the graph shown in fig. 1. 2 . if the output capacity is not reduced when the surrounding air temperature > 5 0c, the device may run into over temperature protection. when activ ated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3 . if the device has to be mounted in any other orientati on, please do not hesitate to contact info@deltapsu.com for more details. 4 . in order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. 5 . depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot!
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 7 d e - rating vs ac i nput v oltage assembly & installation mounting ? mounting holes for power supply assembly onto the mounting surface. p ower supply shall be mounted on minimum 2 mounting holes using m3 screw minimum 5 mm length. ? this surface belongs to customer?s end system or panel where the power supply is mounted. ? connector. installation no output power de - rating across the entire input voltage range ? only use m3 screw 6 mm through the base mounting holes. this is to keep a safe distance between the screw and internal components. ? recommended mounting tightening torque : 4~8kgf.cm fig. 2 mounting orientation
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 8 safety instructions functions graph illustrating the start - up time, rise time, and hold - up time start - up time the time required for the output voltage to reach 90% of its set value, after the input voltage is a pplied. rise time the time required for the output voltage to change from 10% to 90% of its set value. hold - up time hold up time is the time when the ac input collapses and output voltage retains regulation for a certain period of time. the time require d for the output to reach 95% of its set value, after the input voltage is removed. ? to ensure sufficient convection cooling, always maintain a safety distance of > 20mm from all ventilated surfaces while the device is in operation. ? the device is not recommended to be placed on low thermal conductive su rface, for example, plastics. ? note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. do not touch the device while it is in operation or immediately after power is turned off. risk of bu rning! ? do not touch the terminals while power is being supplied. risk of electric shock. ? prevent any foreign metal, particles or conductors to enter the device through the openings during installation. it can cause: - - electric shock; safety hazard; fire; product failure ? warning: when connecting the device, secure earth connection before connecting l and n. when disconnecting the device, remove l and n connect ions before removing the earth connection.
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 9 inrush current inrush current is the first surge current seen on the input side when ac input is applied to the power supply. it is the first pulse captu red; see a typical picture for the inrush current as seen in the power supply. dynamic response the power supply output voltage will remains within 5% of its steady state value, when su bjected to a dynamic load from 0 to 100% of its rated current. overvoltage protection the power supply?s overvoltage circuit will be activated when its internal feedback circuit fails. the output voltage shall not exceed its specifications defined on page 3 under ?protections?. overload & overcurrent prote ctions the power supply?s overload (olp) and over current (ocp) protections will be activated when output current exceeds 1 20% of i o (max load). in such occurrence, the v o will start to droop and once the power supply has reached its maximum power limit, t he protection is activated and the power supply will go into ?hiccup mode? (auto - recovery). the power supply will recover once the fault condition of the olp and ocp is removed and i o is back within the specifications. additionally, if the i o is < 1 2 0 % but > 100% for a prolong period of time (depending on the load), the over temperature protection (otp) will be activated due to high temperature on critical components. the power supply will then go into ?hiccup mode? until power supply cool down. over t emperature protection as mentioned above, the power supply also has over temperature protection (otp). this is activated when the overload condition persists for an extended duration and the output current is below the overload trigger point but > 100% loa d. in the event of a higher operating condition at 100% load, the power supply will run into otp when the surrounding air temperature is > 75c . when activated, the output voltage will go into bouncing mode until the operating surrounding temperature drops to 50c or output capacity is reduced as recommended in the de - rating graph. short circuit protection the power supply?s output olp/ocp function also provides protection against short circuits. when a short circuit is applied, the output current will ope rate in ?hiccup mode?, as shown in the illustration in the olp/ocp section on this page. the power supply will return to normal operation after the short circuit is removed.
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 10 operating mode ? redundancy operation in order to ensure proper redun dancy operation for the power supply unit (psu), ensure that the output voltage difference between the two units is kept at 0.45 ~ 0.50v for 24v supplies. follow simple steps given below to verify: step 1. measure output voltage of psu 1 and psu 2. if psu 1 is the master unit, then v o of psu 1 must be higher than psu 2. in order to set the output voltage, connect the power supply to 50% load and set the psu 1 and psu 2 output voltage. step 2. connect the right drr module, 20a as per the system requirement to the power supply units psu 1 and psu 2 at v in 1 & v in 2 respectively. step 3. connect the system load from v out . please note that output voltage v out from drr module will be = v o (output voltage of power supply) ? v drop * (in drr module). fig. 3 redundancy / parallel operation connection diagram ? parallel operation these drr modules can also be used for parallel function in order to increase the output power by n+1 (e.g. 2.5a + 2.5a = 5a or 2.5a + 2.5a + 2.5a = 7.5a) or current sharing, and thus increasing the power supply and system reliability. though the pmc - 24v100w1ax is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple st eps as below (refer to fig. 3 for the connection diagram). step 1. set output load condition for both supplies at 50% and measure the output voltages. step 2. adjust output voltages to the same level or within 25mv difference. step 3. connect psu 1 and psu 2 with the drr - 20a module and measure at v in 1 & v in 2 to verify the voltage difference. ensure the voltages are within 25mv. step 4. output voltage from drr module v out will be = v o (output voltage of power supply) ? v drop * (in drr module). *v drop will v ary from 0.60v to 0.90v (typical 0.65v) depending on the load current and surrounding air temperature.
technical d at asheet pmc panel mount power supply 24v 10 0 w 1 phase / pmc -24v 100 w1a x all parameters are specified at 25c ambient unless otherwise noted. www.deltapsu.com ( m arch 2013 , rev. 00 ) 11 others delta rohs compliant restriction of the u sage of hazardous substances the european directive 2011/65/e u limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants pbb and pbde for the use in electrical and electronic equipmen t. rohs is the abbreviation for ?restriction of the use of certain hazardous substances in electrical and electronic equipment?. this product conforms to this standard. pfc ? norm en 61000 -3 -2 line current harmonic typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. in industrial environment, complying with en 61000 - 3 - 2 is only necessary under special conditions. complying to this standard can have some technical drawbacks, such as lower eff iciency as well as some commercial aspects such as higher purchasing costs, frequently, the user does not profit form fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. thi s product conforms to this standard.
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: delta: ? PMC-24V100W1AA


▲Up To Search▲   

 
Price & Availability of PMC-24V100W1AA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X